Sign In | Join Free | My isp.org.cn
China Shenzhen Voboal Industrial Automation Co., Ltd. logo
Shenzhen Voboal Industrial Automation Co., Ltd.
Provide one-stop industrial control spare parts warehouse for customers
Verified Supplier

2 Years

Home > PLC SIMATIC S7-1500 >

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

Shenzhen Voboal Industrial Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

Brand Name : SIEMENS

Model Number : 6ES7518-4FX00-1AB0

Certification : CE

Place of Origin : Germany

MOQ : 1

Price : USD

Payment Terms : L/C, T/T

Supply Ability : 100

Delivery Time : 10-12Days

Packaging Details : 15,10 x 15,40 x 4,60

Communication Interfaces : PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, TCP/IP

Number Of Analog Inputs : Up to 32

Number Of Digital Inputs : Up to 256

Cpu Type : S7-1500

Dimensions : Standard: 90 x 100 x 75 mm, Compact: 60 x 100 x 75 mm

Power Supply : 24 V DC

Number Of Analog Outputs : Up to 32

Certifications : CE, UL, CSA

Number Of Digital Outputs : Up to 256

Programming Software : TIA Portal

Protection Rating : IP20

Programming Languages : Ladder Logic, Function Block Diagram, Structured Control Language, Statement List

Memory : Up to 4 MB

Operating Temperature : -25°C to 60°C

Contact Now

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC

Understood. Here are the key details about the SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT controller module:

Product Description:
- The 6ES7518-4FX00-1AB0 is a SIMATIC S7-1500 CPU module with PROFINET RT (Real-Time) and PROFIBUS connectivity.
- It features 3 Ethernet interfaces for PROFINET RT communication and a 4th interface for PROFIBUS with 1ns bit performance.
- This module, like the previous ones, requires a SIMATIC memory card for program storage and additional functionality.

Key Features:
- PROFINET RT (Real-Time) services for deterministic, time-critical Ethernet-based communication.
- 3 x Ethernet interfaces for PROFINET RT connectivity.
- 4th interface for PROFIBUS with 1ns bit performance for high-speed, deterministic communication.
- Suitable for time-critical applications such as motion control and manufacturing processes.
- Integrated PROFIBUS master functionality.
- Requires a SIMATIC memory card for program storage and additional features.
- Powerful CPU with 4 MB work memory and 20 MB load memory.

Connectivity:
- 3 x Ethernet/PROFINET RT interfaces for deterministic, real-time Ethernet communication.
- 1 x PROFIBUS interface for connecting PROFIBUS devices and networks.

Performance:
- 1ns bit performance on the PROFIBUS interface for high-speed, deterministic communication.
- Enables precise control and synchronization of connected devices.

SIMATIC Memory Card:
- The 6ES7518-4FX00-1AB0 module requires a SIMATIC memory card for program storage and additional functionality.
- The memory card provides the necessary storage capacity and enables features like firmware updates, backup, and restore functionality.

Certifications:
- According to the information available, the 6ES7518-4FX00-1AB0 module likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- IEC 61784-2 (PROFINET)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals

In summary, the SIEMENS 6ES7518-4FX00-1AB0 is a PROFINET RT and PROFIBUS controller module with 1ns bit performance on the PROFIBUS interface, designed for high-speed, deterministic communication in SIMATIC S7-1500 automation systems. It requires a SIMATIC memory card for program storage and additional functionality.

General information
Product type designation CPU 1518F-4 PN/DP MFP
HW functional status FS03
Firmware version V2.9
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central)
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V17 (FW V2.9) / V15 (FW V2.5) or higher
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 6
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 1.7 A
Current consumption, max. 2 A
Inrush current, max. 2.7 A; Rated value
I²t 0.02 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 35 W
Power loss
Power loss, typ. 29 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 9 Mbyte
● integrated (for data) 60 Mbyte
● integrated (for CPU function library of CPU Runtime) 50 Mbyte; Note: The "CPU function library of the CPU" are C/C++ blocks for the user program that were created using the SIMATIC ODK 1500S or Target 1500S.
Working memory for additional functions
● Integrated (for C/C++ Runtime application) 512 Mbyte
● available (for Linux runtime application) 1 Gbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte; the memory card must have at least 2 GB of space on it
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 1 ns
for word operations, typ. 2 ns
for fixed point arithmetic, typ. 2 ns
for floating point arithmetic, typ. 6 ns
CPU-blocks
Number of elements (total) 20 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
FC
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
OB
● Size, max. 1 Mbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With Failsafe, two RTGs with one "Cyclic interrupt OB" or one "Free cycle OB" (F-OB) each are possible
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 3
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Extended retentive data area (incl. timers, counters, flags), max. 20 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 16 384; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
— Outputs (volume) 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated 1
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated 2
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max. 32; CPU + 31 modules
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● to DP, master Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 3
Number of PROFIBUS interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1
● Number of ports 2
● integrated switch Yes
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes; MRP Automanager according to IEC 62439-2 Edition 2.0
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 512
— of which in line, max. 512
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 125 µs 125 µs
— for send cycle of 187.5 µs 187.5 µs
— for send cycle of 250 µs 250 µs to 4 ms
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of "odd" send cycles Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT Yes; Minimum send cycle of 250 µs
— PROFIenergy Yes; per user program
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
2. Interface
Interface types
● RJ 45 (Ethernet) Yes; X2
● Number of ports 1
● integrated switch No
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy No
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode No
— Direct data exchange No
— IRT No
— PROFIenergy Yes; per user program
— Prioritized startup No
— Number of connectable IO Devices, max. 128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT No
— PROFIenergy Yes; per user program
— Prioritized startup No
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC


Cheap SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC wholesale

SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Voboal Industrial Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)