SIEMENS 6ES7512-1SM03-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 * *** APPROVALS AND CERTIF

Brand Name : SIEMENS

Model Number : 6ES7512-1SM03-0AB0

Certification : CE

Place of Origin : Germany

MOQ : 1

Price : USD

Payment Terms : L/C, T/T

Supply Ability : 100

Delivery Time : 10-12Days

Packaging Details : 15,10 x 15,40 x 4,60

Memory : 4 MB

Number Of Digital Inputs : 32

Number Of Digital Outputs : 32

Cpu Type : S7-1500

Number Of Technology Modules : 8

Power Supply : 24V DC

Programming Software : TIA Portal

Number Of Analog Outputs : 16

Number Of Communication Interfaces : 2

Operating System : Windows 7/10

Programming Languages : Ladder Logic, Function Block Diagram, Structured Control Language

Communication Protocols : PROFINET, PROFIBUS, Modbus TCP, Ethernet/IP

Number Of Analog Inputs : 16

Integrated Functions : Web server, OPC UA server, Safety Integrated

Contact Now

SIEMENS 6ES7512-1SM03-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 * *** APPROVALS AND CERTIF

Understood, the details you provided are for the SIEMENS 6ES7512-1SM03-0AB0 SIMATIC S7-1500 CPU module:

Product Description:
- The 6ES7512-1SM03-0AB0 is a SIMATIC S7-1500 CPU module.
- It requires a SIMATIC memory card for program storage and additional functionality.
- Busadapters are required for the module's Port 1 and Port 2 interfaces.

Key Features:
- SIMATIC S7-1500 CPU module with specific processing capabilities.
- Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
- Supports the use of busadapters for the module's communication ports.

Connectivity:
- The module has at least 2 communication ports (Port 1 and Port 2) that require busadapters for connectivity.
- The busadapters enable the use of various communication protocols and fieldbus systems, such as PROFINET, PROFIBUS, or other industrial Ethernet standards.

SIMATIC Memory Card:
- The 6ES7512-1SM03-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
- The memory card provides the necessary storage capacity and enables advanced features of the CPU module.

Busadapters:
- Busadapters are required for the module's Port 1 and Port 2 communication interfaces.
- These adapters allow the CPU module to connect to and communicate over different industrial communication networks and fieldbuses.

Approvals and Certifications:
- As a SIMATIC S7-1500 CPU module, the 6ES7512-1SM03-0AB0 likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- IEC 61784-2 (PROFINET)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
- Any other relevant industry-specific certifications and standards required for the intended application and geography.

Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7512-1SM03-0AB0 SIMATIC S7-1500 CPU module, including the approvals and certifications.

General information
Product type designation CPU 1512SP F-1 PN
HW functional status FS01
Firmware version V3.0
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Multi-hot swapping
● Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V18 (FW V3.0); with older TIA Portal versions configurable as 6ES7 512-1SK01-0AB0
Configuration control
via dataset Yes
Control elements
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms
Input current
Current consumption (rated value) 0.51 A
Current consumption, max. 0.7 A
Inrush current, max. 1.34 A; Rated value
I²t 0.3 A²·s
Power
Infeed power to the backplane bus 8.05 W
Power loss
Power loss, typ. 3.5 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 600 kbyte
● integrated (for data) 2 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 25 ns
for word operations, typ. 32 ns
for fixed point arithmetic, typ. 42 ns
for floating point arithmetic, typ. 170 ns
CPU-blocks
Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 2 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 600 kbyte
FC
● Number range 0 ... 65 535
● Size, max. 600 kbyte
OB
● Size, max. 600 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24; Up to 8 possible for F-blocks
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 256 kbyte; in total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 216 KB
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 2 048; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Address space per module
● Address space per module, max. 288 byte; For input and output data respectively
Address space per station
● Address space per station, max. 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
Hardware configuration
Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● Via CM 1
Number of IO Controllers
● integrated 1
● Via CM 0
Rack
● Modules per rack, max. 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
● Quantity of operable ET 200SP modules, max. 64
● Quantity of operable ET 200AL modules, max. 16
● number of rack tiers / usable / maximum 1
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● to DP, master Yes; Via CM DP module
● to DP, slave Yes; Via CM DP module
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 1
Number of PROFIBUS interfaces 1; Via CM DP module
Optical interface No
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
● Number of ports 3; 1. integr. + 2. via BusAdapter
● integrated switch Yes
● BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
— for send cycle of 500 µs 500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of "odd" send cycles Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT Yes
— PROFIenergy Yes; per user program
— Shared device Yes
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
2. Interface
Interface types
● RS 485 Yes; Via CM DP module
● Number of ports 1
Protocols
● PROFIBUS DP master Yes
● PROFIBUS DP slave Yes
● SIMATIC communication Yes
PROFIBUS DP master
● Number of connections, max. 48; Of which 4 each reserved for ES and HMI
● Number of DP slaves, max. 125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Services
— PG/OP communication Yes
— Equidistance No
— Isochronous mode No
— Activation/deactivation of DP slaves Yes
Interface types
RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
● Industrial Ethernet status LED Yes
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
PROFIsafe Yes; V2.4 / V2.6
Number of connections
● Number of connections, max. 128; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web 10
● Number of connections via integrated interfaces 88
● Number of connections per CP/CM 32
● Number of S7 routing paths 16
Redundancy mode
● H-Sync forwarding Yes
Media redundancy
— Media redundancy Yes; only via BusAdapter
— MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPD Yes; Requirement: IRT
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● PG/OP communication Yes; encryption with TLS V1.3 pre-selected
● S7 routing Yes
● Data record routing Yes
● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; max. 78 multicast circuits
● DHCP Yes
● DNS Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
● Encryption Yes; Optional
Web server
● HTTP Yes; Standard and user pages
● HTTPS Yes; Standard and user pages

SIEMENS 6ES7512-1SM03-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 * *** APPROVALS AND CERTIF


Cheap SIEMENS 6ES7512-1SM03-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 * *** APPROVALS AND CERTIF wholesale

SIEMENS 6ES7512-1SM03-0AB0 SIMATIC MEMORY CARD REQUIRED, BUSADAPTER REQUIRED FOR PORT 1 AND 2 * *** APPROVALS AND CERTIF Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Voboal Industrial Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)